高溫VES轉(zhuǎn)向劑測(cè)試
VES轉(zhuǎn)向劑-2025.3.15 測(cè)試方法及測(cè)試結(jié)果
VES轉(zhuǎn)向劑-2025.3.15,在配方條件下,在140度條件下2個(gè)小時(shí)仍保持200CP以上粘度,保證了140度2小時(shí)保持75CP的粘度要求。
測(cè)試方法以及測(cè)試結(jié)果如下:
VES Diverting Agent - March 15, 2025. Under the specified formulation conditions, the agent maintained a viscosity of over 200 cP for 2 hours at 140°C, thereby ensuring compliance with the viscosity requirement of 75 cP under the same temperature and duration.
The testing method and results are as follows:
一 測(cè)試方法
I. Testing Methods
1、基液配制:在20%鹽酸以及其它助劑配合條件下進(jìn)行測(cè)試。
1. Base Fluid Preparation
The test was conducted under the conditions of 20% hydrochloric acid combined with other additives.
2、流變性能測(cè)試
將殘酸洗液轉(zhuǎn)移到流變儀中,將溫度從25℃提高到140℃溫度,升溫溫度梯度為3℃/min,剪切速率為100s-1。升溫至140度后,保持溫度2個(gè)小時(shí),整個(gè)測(cè)試共計(jì)時(shí)間大約150分鐘。
2. Rheological Performance Testing
The residual acid solution was transferred to a rheometer. The temperature was increased from 25°C to 140°C at a heating rate of 3°C/min under a shear rate of 100 s?1. After reaching 140°C, the temperature was maintained for 2 hours. The total test duration was approximately 150 minutes.
二 測(cè)試結(jié)果
II. Test Results